Portable phosphine gas detector British Cisco GB Pro U.S. imports PH3 analyzer | Инструменты



Сохраните в закладки:

Цена:RUB
*Стоимость могла изменится

Количество:


Новое поступление

Характеристики

Portable phosphine gas detector British Cisco GB Pro U.S. imports PH3 analyzer | Инструменты

История изменения цены

*Текущая стоимость уже могла изменится. Что бы узнать актуальную цену и проверить наличие товара, нажмите "Добавить в корзину"

Месяц Минимальная цена Макс. стоимость Цена
Mar-18-2026 0.38 руб. 0.26 руб. 0 руб.
Feb-18-2026 0.62 руб. 0.13 руб. 0 руб.
Jan-18-2026 0.64 руб. 0.75 руб. 0 руб.
Dec-18-2025 0.29 руб. 0.38 руб. 0 руб.
Nov-18-2025 0.36 руб. 0.57 руб. 0 руб.
Oct-18-2025 0.6 руб. 0.95 руб. 0 руб.
Sep-18-2025 0.97 руб. 0.92 руб. 0 руб.
Aug-18-2025 0.53 руб. 0.1 руб. 0 руб.
Jul-18-2025 0.49 руб. 0.0 руб. 0 руб.

Описание товара

Portable phosphine gas detector British Cisco GB Pro U.S. imports PH3 analyzer | ИнструментыPortable phosphine gas detector British Cisco GB Pro U.S. imports PH3 analyzer | Инструменты


GasBadge ® Pro to British Cisco highest quality and reliability standards designed to provide lifelong protection of dangerous gases , functions than any other existing single gas detection equipment. Can replace the use of \"smart\" sensors enable GasBadge ® Pro to quickly adapt to the security level of the non- recognition of oxygen or any of the following toxic gases : carbon monoxide, hydrogen sulfide , nitrogen dioxide , sulfur dioxide , chlorine , chlorine dioxide, phosphine , ammonia , hydrogen cyanide and hydrogen .   GasBadge ® Pro to communicate directly via infrared interface to optional accessories such as the Docking Station , a data connection (Datalink), and infrared printers continue to simplify and automate calibration , function ( shock ) testing and data download . Standard short-term exposure level (STEL), time-weighted average (TWA) and a year-long survey data logging capabilities , comes with an event recorder to record the last 15 alarm events.  

The product with shell shock , from radio frequency interference , and has a waterproof and durable characteristics . Shock protection layer to protect the product from all types of damage to the harsh working environment . Its ease of use and sensitive four -button navigation can be easily installed setup, operation , and calibration functions.

Performance Advantage
Running time A minimum of 2,600 hours of continuous operation , the power supply : replaceable CR2 lithium battery.  
   
Display Users can display real-time readings directly on the screen after the configuration ( unit : ppm or % content ) (O2) , Or only gas type .  
   
Display Size Direct gas readings screen is a single gas detection instrument used in the display of the largest and best visibility . Icon to make the user interface simple and refreshing , can be easily understood around the world .  
   
Time Weighted Average (TWA) and Short Term Exposure Limit (STEL) TWA and STEL values currently viewing as GasBadge®Pro standard.    
   
TWA and STEL alarms User-adjustable . Time Weighted Average (TWA) and Short Term Exposure Limit (STEL) alarms User-adjustable , ensuring the customized equipment of the set point is exceeded will enter alarm status , alarm status prompts the user what happened.  
   
Data records Standard one-year ( minimum ) data record energy ( the industry's largest memory ) .  
   
Data recording interval can be adjusted Recording interval can be adjusted so that the user can select the instrument recording frequency information .  
   
GasBadge ® data connection GasBadge data link is an optional accessory , enabling alarm events , equipment details and health data ( via USB) to your computer for immediate download.  
   
DS2 Docking Station compatible Data DS2 Docking Station (DS2 Docking Station) is GasBadge®Pro 's optional accessories . Independent instrument docking station (IDS) provides automatic instrument calibration , data maintenance , diagnostics and data download function . Use a central database to store all the information to prepare for archiving or printing. Link up to 100 IDS modules - can be connected to thousands of instruments.  
   
Display backlight Users simply press a button , you can view the current gas reading in poor light conditions. When an alarm condition occurs , the alarm light will flash as a hazardous condition exists another way of reminder .  
   
Four-button operation Users can easily configure the instrument . GasBadge Pro provides the most convenient for the user to select any single gas detection equipment.  
   
Sensor Options Interchangeable \"smart\" sensors oxygen or any of the following toxic gases : CO, H2S, O2, NO2, SO2, Cl2, ClO2, PH3, NH3, H2, CO/H2 ( zero ) , and more .  
   
Waterproof GasBadge®Pro waterproof , make sure to protect equipment from the impact of outdoor environmental conditions , such as: rain , fog and other harsh industrial applications situations when flushing formation. Its design meets IP67  
   
Event Log GasBadge®Pro will continue to record the last 15 alarm events. When the event log is full , it will automatically overwrite the old written records .  
   
Infrared printer interface Infrared interface allows the device to easily print event logs contain POS printer infrared port.  
   
User-adjustable alarm Low-level and high-level alarm set points can be fully adjusted by the user. This enables the user to set the instrument alarm function according to their own corporate standards.  
   
Top- mounted sensor Even if placed in a shirt pocket, it can also provide continuous uninterrupted protection.  
   
Sensor over-range protection Ensure that the sensor can be protected when exposed to high concentrations of gas . Over-range condition occurs when the instrument will prompt the user \"OR\".  
   
Powerful audible alarm with vibration and visual alarm function ( standard configuration ) . Standard Treble ( 95 db ) audible alarm ; bright visual alarm display can be seen from all directions ; If there is a dangerous state , will start vibrating alarm to prompt the user .  
   
Small size (3.7 x 2 x 1.1) (94 mm x 50.8 mm x 27.9 mm) Compact , can do all kinds of fixtures in the body, without affecting comfort ; or can be placed in the front shirt pocket . Top- mounted sensor will not be affected by the performance of the pocket cover .  
   
Light weight - 3.0 ounces ( 85 grams ) The device weighs only 3.0 ounces ( 85 grams ) , can be comfortably worn on any part of the body .  
   
Vibration protective shell Protective rubber filler makes the device extremely durable and just the right it is very convenient.  
   
detection The instrument detects sustainable while maintaining the highest gas readings ( sensor since the last peak in contact with a gas purge ) visibility within the site.  
   
Recent calibration instructions \"From the time of last calibration \" feature allows end users to view the number of days since the last calibration .  
   
Life indicator GasBadge®Pro continuously monitors and displays the remaining life of the instrument until the instrument is completely inoperable.  
   
Staples Each GasBadge®Pro is equipped with a belt clip and spring ( standard configuration ) . Other accessories ( such as: totes and lanyard ) are also available for purchase.  
   
Anti-electromagnetic interference (EMI) / RFI (RFI) From cell phones , handheld radios and other electronic equipment from external RF interference will not cause an error alarm.  
   
Self-Test Automatic self-test function to ensure correct operation of instruments, sensors and circuits . Users can start assist function tests to ensure the normal operation of the alarm function .  
   
End of Life Warning When the remaining battery life for seven days , the empty battery icon will blink to alert the user that the equipment life is about to end. When the remaining life of four hours , the user will get a breath every 15 seconds warning prompted an empty battery icon flashes at the same time . Two kinds of alarms are user notice : Please replace the device .  
   
Ongoing operating performance \" on\" capability allows end users to set the instrument to the venue can not be closed mode. So , the instrument will continue to run until the battery runs out .  
   
Overdue calibration instructions This feature enables the user to set the alarm indication to prompt the end user : the instrument has to be calibrated .  
   

Housing:

Rugged, waterproof polycarbonate shell with protective rubber padding . Anti RF interference .

Size :

3.2 x 1.9 x 1.1(81.3 mm x 48.3 mm x 27.9 mm)

Weight:

3 oz. (85 gram)

Range :
Gas Chemical Formula Range Resolution

Carbon monoxide

CO

0-1,500

1 ppm

Hydrogen sulfide

H2S

0-500ppm

0.1 ppm

Oxygen

O2

0-30% by volume

0.1%

Nitrogen dioxide

NO2

0-150ppm

0.1 ppm

Sulfur dioxide

SO2

0-150ppm

0.1 ppm

Ammonia

NH3

0-100ppm

1 ppm

Chlorine

Cl2

0-100ppm

0.1 ppm

Chlorine dioxide

ClO2

0-2ppm

0.01 ppm

Hydrogen cyanide

PH3

0-10ppm

0.01 ppm

Hydrogen cyanide

HCN

0-30ppm

0.1 ppm

Hydrogen

H2

0-2,000 ppm

1 ppm

Display:

Custom display with icons LCD display, easy to use.
Segmented direct gas readings displayed.
Suitable for backlight low light environments.
\" Go / no- continue \" display mode.
Leak reading instructions.

Alarm:

Low / high alarm device selected by the user .
Bright lights, loud audible alarm device type (95 dB ) and vibrating alarm device .

Battery ( run time) :

User -replaceable 3V, CR2 lithium battery
Conventional follows: run time of up to 2,600 hours ( at least )

Event Log:

Continuous operation . Record last 15 alarm events , incidents visible leaks gas concentration , time, duration , and during the event .
Event records can be viewed on a computer , or from the instrument to an infrared printer to print directly .

Data recording :

Year interval is one minute

Temperature range:

Under General : -40 º to 60 º C (-40 º to 140 º F)

Humidity range:

General under :0-99% RH ( non-condensing )

Certification:

UL and cUL:
- I grade, class 1, A, B, C, D groups ; T4
- I Class , Zone 0 , AEx ia IIC T4

CSA:
- I grade, class 1, A, B, C, D groups ; T4
- EEx ia IIC T4

ATEX:
- Intrinsic Safety : Safety : EEx ia I / IIC T4
- Equipment Group and Category : II 1G; I M2
- Electromagnetic compatibility (EMC): EN50270

Performance : O2(EN50104); CO, H2S, (EN45544) ( to be confirmed )
Australia : Ex ia I / IIC T4
IEC: Ex ia IIC T4
Russia : GOST-R Certification ( pending )
CO, H2S, SO2, O2, NO2, NH3, Cl2, ClO2, PH3, HCN, H2   Carbon monoxide, hydrogen sulfide, sulfur dioxide, oxygen, nitrogen dioxide , ammonia , chlorine, chlorine dioxide , phosphine , hydrogen cyanide , hydrogen


Смотрите так же другие товары: